Aperflux 851 Pressure Regulator
When requesting information, please download the Fillable PDF to provide details about your regulator use case. Instructions for completing the form are found in the footer of the document. Once completed, please upload the document with the Request for Information.
Hydrogen Compatible
Description
The Aperflux 851 is pilot-controlled pressure regulator for medium and high pressure applications.
Aperflux 851 is normally a fail open regulator and will open specifically under the following conditions:
- If the main diaphragm fails
- If there is no feed to the pilot loop
This regulator is suitable for use with previously-filtered, non-corrosive gases.
Features- Design pressure: up to 14,50 PSIG (100 bar)
- Temperature: Pietro Fiorentini regulators are suitable for a minimum operating ambient temperature -40° to 140° F with a Carbon Steel Body
- If the following conditions are met:
- Inlet flowing gas temperature shall be always higher than -4° F
- Inlet flowing gas shall be filtered, clean and without any liquid impurities
- Range of inlet pressure bpe: 18.8 to 1,230 PSIG (1.3 to 85 bar)
- Range of outlet pressure Wh: 12 to 1,073 PSIG (0.8 to 74 bar) depending on installed pilot
- Minimum working differential pressure: 7.25 PSIG (0.5 bar) - Recommended > 30 PSIG (2 bar)
- Accuracy class AC: up to 1% > Closing pressure class SG: from 5% to 1.5% depending on outlet pressure
- Available size DN: 1” -2” -3” -4” -6” -8” -10”
- Flanging: class 150-300-600 RF or RTJ according to ANSI b16.5 and PN16 according to ISO 7005
Specifications
Specifications
Hydrogen Compatibility %
Hydrogen Compatible up to 100% Hydrogen Compatible up to 30% Hydrogen Compatible up to 20%
Accuracy Class
- Up to 5
Available Size DN
- 1”
- 2”
- 3”
- 4”
- 6”
- 8”
- 10”
Closing Pressure Class SG
- Up to 10 %
Design Pressure
- up to 102 bar
Design Temperature
- -20° to +60° C
Flanging
- Class 150 RF According to ANSI B16.5 and PN 16 According to ISO 7005
Maximum Working Differential Pressure
- 87.5 bar
Minimum Working Differential Pressure
- 0.5 bar
Outlet Pressure Range of Wd
- 12 to 1,073 psig
Range of Inlet Pressure Bpu
- 1.3 to 85 bar