FE 75/100 Pressure Regulator

Brand: Pietro Fiorentini S.p.A.

When requesting information, please download the Fillable PDF to provide details about your regulator use case. Instructions for completing the form are found in the footer of the document. Once completed, please upload the document with the Request for Information.

CSA CSA Measurement Canada Measurement Canada
Hydrogen Compatible Hydrogen Compatible

The FE75 / FE100 is a two-stage gas pressure regulator by Pietro Fiorentini. It is particularly suitable for low pressure natural gas distribution networks for residential and commercial users. It should be used with previously filtered non-corrosive gases including biomethane and natural gas blended with hydrogen.

According to the European Standard EN 334, it is classified as Fail Close because it is always supplied with an overpressure protection device (slam shut valve).

The FE75 / FE100 is Hydrogen Ready for NG-H2 blending.

Features
  • Accuracy class AC: 10
  • Connections: in-line 1”, 1”1/2 NPT according to ANSI B1.20.1, other configurations or connections on request
  • Lock-up pressure class SG: 20, minimum  3” wc |0.75 kPa
  • Design pressure: 125 psig | 0.86 MPa
  • Inlet pressure: from 7.25 psig to 125 psig | 50 KPa to 0.86 MPa
  • Ambient temperature: standard version from -20°F to +150°F | -30°C to +65°C, arctic version from -40°F to +150°F | -40°C to +65°C
  • Range of downstream pressure:
    • Wds from 5” w.c. to 2.3 psig | 1.3 kPa to 16 kPa for BP, from 2 psig to 5.1 psig | 14 KPa to 35 kPa for MP
    • Wdso from 12.6” w.c. to 3.35 psig | 3.2 kPa to 23.1 kPa for BP, from 3 psig to 8 psig | 21 kPa to 55.2 kPa for MP
    • Wdsu from 2.4″ w.c. to 3.6 psig | from 0.6 kPa to 25 kPa from BP

The FE75 / FE100 is a two-stage gas pressure regulator by Pietro Fiorentini. It is particularly suitable for low pressure natural gas distribution networks for residential and commercial users. It should be used with previously filtered non-corrosive gases including biomethane and natural gas blended with hydrogen.

According to the European Standard EN 334, it is classified as Fail Close because it is always supplied with an overpressure protection device (slam shut valve).

The FE75 / FE100 is Hydrogen Ready for NG-H2 blending.

Features
  • Accuracy class AC: 10
  • Connections: in-line 1”, 1”1/2 NPT according to ANSI B1.20.1, other configurations or connections on request
  • Lock-up pressure class SG: 20, minimum  3” wc |0.75 kPa
  • Design pressure: 125 psig | 0.86 MPa
  • Inlet pressure: from 7.25 psig to 125 psig | 50 KPa to 0.86 MPa
  • Ambient temperature: standard version from -20°F to +150°F | -30°C to +65°C, arctic version from -40°F to +150°F | -40°C to +65°C
  • Range of downstream pressure:
    • Wds from 5” w.c. to 2.3 psig | 1.3 kPa to 16 kPa for BP, from 2 psig to 5.1 psig | 14 KPa to 35 kPa for MP
    • Wdso from 12.6” w.c. to 3.35 psig | 3.2 kPa to 23.1 kPa for BP, from 3 psig to 8 psig | 21 kPa to 55.2 kPa for MP
    • Wdsu from 2.4″ w.c. to 3.6 psig | from 0.6 kPa to 25 kPa from BP

Specifications

Certifications & Approvals

CSA CSA Measurement Canada Measurement Canada

Body Material

  • Aluminum Al GD-AlSI - EN AB 46100

Cover Material

  • Aluminum Al GD-AlSI - EN AB 46100

Weight

  • 2.6 ÷ 2.9 kg

Nominal Capacity

  • 50 to 100 stm³/h