Images are representations only.

Detecto Pak-Infrared+ (DP-IR+™)

Brand: Heath Consultants Incorporated
The DP-IR+ is the latest generation of leak survey instruments from Heath that will greatly improve the productivity and safety of a walking/mobile survey because of high sensitivity and fast response.

It is an extremely sensitive, advanced leak detector capable of detecting methane without false alarming on other gases.

The DP-IR+ operates under a variety of environmental conditions including cold or hot weather.

Its rugged design will stand up to normal field use and operating conditions.
show more
The DP-IR+ is the latest generation of leak survey instruments from Heath that will greatly improve the productivity and safety of a walking/mobile survey because of high sensitivity and fast response.

It is an extremely sensitive, advanced leak detector capable of detecting methane without false alarming on other gases.

The DP-IR+ operates under a variety of environmental conditions including cold or hot weather.

Its rugged design will stand up to normal field use and operating conditions.

Specifications

Detection Method

  • Infrared Controlled Interference
  • Polarization Spectrometer

Measurement Range

  • 0 to 10,000 ppm, 1 to 100% Gas

Display Range

  • Auto Ranging: ppm: 0-10,000, %Gas: 1 - 100%
  • Manual Ranging: ppm scale: 0-10,000, %Gas scale: 0 - 100%

Sensitivity

  • 1 ppm

Resolution

  • 0-1000 ppm: 1 ppm
  • 1000-10,000 ppm: 5 ppm
  • 1-100 %Gas: 0.1%

Accuracy

  • Greater of ± 0.5% or ± 10% of Reading (normal temperature and pressure, % gas on manual mode)

Response Time

  • PPM Mode: T10< 0.7 s, T50< 1.3 s
  • PPM Mode with Survey Probe: T10< 1.2 s, T 50 < 1.8 s
  • %Gas Mode with Method 21 Probe: T 50 < 1.8 s, T 90 < 2.5 s, Recovery Time T 10 < 2.0 s

Sample Flow Rate

  • 2.0 LPM (with Survey Probe attached)

Connectivity

  • Bluetooth 5 Low Energy (BLE) (compatible with iOS, Android and Windows® devices)

Detection Alarms Modes

  • Digital Methane Detection (DMD): Audible tone when detection threshold exceeded
  • Digital Methane Detection (DMD): Adjustable Alarm Level from 1 to 9,000 ppm
  • Tick: Continuous audio tone relative to concentration

System Fault Warning

  • Audible tone and indication on the display

Self Test & Calibration

  • Built in Self Test and Calibration function verifies operation and adjusts calibration for Max. sensitivity. Test gas cell integrated within the instrument.

Compliance

  • Conducted Emissions Class B
  • Radiated Emissions Class B
  • ANSI C63.4 Class B
  • FCC 47 CFR Part 15 Class B
  • EN 61326-1
  • EN 61000-4-2 4 kV/8 kV
  • EN 61000-4-3 3 V/M

Dust Filter

  • Replaceable filter provides dust protection. Easy change-out quick disconnect filter cap.

Display

  • Large easy to read backlit LCD (0.75” Numeric)

Operating Temperature

  • 0°F to + 122°F (-17°C to 50°C) (Nominal Battery Voltage)

Humidity

  • 5 to 95% RH, non-condensing

Enclosure

  • IP54 (Water splash and Dust resistant)

Instrument Weight

  • 5.6 lbs

Carry Case

  • 13 lbs empty, 21 lbs filled 24.5” x 21” x 9”

Power Supply

  • Internal rechargeable Li-ion battery or External 12 Vdc car battery with power conditioner

Battery Operating Life

  • 8 hours at 32°F without backlight on

Battery Charger

  • External, in-line, 110 - 240 Vac, 50 / 60 hertz. 10 hours to 90% charge

Shoulder Strap

  • Single over the shoulder padded strap

Alarm Volume

  • 108 dBs @ Alarm port (A-fast)

Survey Probe

  • Quick connect fitting with locking clasp. Adjustable length from 25” to 41”

Bar Hole Probe

  • Standard: 20”, Optional 36”

Method 21 Probe (Optional)

  • Standard: 5’, with quick connect fitting and locking clasp

Intrinsic Safety

  • Class I Division I Group D T3UL 913, CSA 22.2 No. 157, MET Labs #E112840