Description
The DP-IR+ is the latest generation of leak survey instruments from Heath that will greatly improve the productivity and safety of a walking/mobile survey because of its high sensitivity and fast response.
It is an extremely sensitive, advanced leak detector capable of detecting methane without false alarms for other gases.
The DP-IR+ operates under a variety of environmental conditions, including cold or hot weather.
Its rugged design will stand up to normal field use and operating conditions.
Configure
Specifications
Specifications
Detection Method
- Infrared Controlled Interference
- Polarization Spectrometer
Measurement Range
- 0 to 10,000 ppm, 1 to 100% Gas
Display Range
- Auto Ranging: ppm: 0-10,000, %Gas: 1 - 100%
- Manual Ranging: ppm scale: 0-10,000, %Gas scale: 0 - 100%
Sensitivity
- 1 ppm
Resolution
- 0-1000 ppm: 1 ppm
- 1000-10,000 ppm: 5 ppm
- 1-100 %Gas: 0.1%
Accuracy
- Greater of ± 0.5% or ± 10% of Reading (normal temperature and pressure, % gas on manual mode)
Response Time
- PPM Mode: T10< 0.7 s, T50< 1.3 s
- PPM Mode with Survey Probe: T10< 1.2 s, T 50 < 1.8 s
- %Gas Mode with Method 21 Probe: T 50 < 1.8 s, T 90 < 2.5 s, Recovery Time T 10 < 2.0 s
Sample Flow Rate
- 2.0 LPM (with Survey Probe attached)
Connectivity
- Bluetooth 5 Low Energy (BLE) (compatible with iOS, Android and Windows® devices)
Detection Alarms Modes
- Digital Methane Detection (DMD): Audible tone when detection threshold exceeded
- Digital Methane Detection (DMD): Adjustable Alarm Level from 1 to 9,000 ppm
- Tick: Continuous audio tone relative to concentration
System Fault Warning
- Audible tone and indication on the display
Self Test & Calibration
- Built in Self Test and Calibration function verifies operation and adjusts calibration for Max. sensitivity. Test gas cell integrated within the instrument.
Compliance
- Conducted Emissions Class B
- Radiated Emissions Class B
- ANSI C63.4 Class B
- FCC 47 CFR Part 15 Class B
- EN 61326-1
- EN 61000-4-2 4 kV/8 kV
- EN 61000-4-3 3 V/M
Dust Filter
- Replaceable filter provides dust protection. Easy change-out quick disconnect filter cap.
Display
- Large easy to read backlit LCD (0.75” Numeric)
Operating Temperature
- 0°F to + 122°F (-17°C to 50°C) (Nominal Battery Voltage)
Humidity
- 5 to 95% RH, non-condensing
Enclosure
- IP54 (Water splash and Dust resistant)
Instrument Weight
- 5.6 lbs
Carry Case
- 13 lbs empty, 21 lbs filled 24.5” x 21” x 9”
Power Supply
- Internal rechargeable Li-ion battery or External 12 Vdc car battery with power conditioner
Battery Operating Life
- 8 hours at 32°F without backlight on
Battery Charger
- External, in-line, 110 - 240 Vac, 50 / 60 hertz. 10 hours to 90% charge
Shoulder Strap
- Single over the shoulder padded strap
Alarm Volume
- 108 dBs @ Alarm port (A-fast)
Survey Probe
- Quick connect fitting with locking clasp. Adjustable length from 25” to 41”
Bar Hole Probe
- Standard: 20”, Optional 36”
Method 21 Probe (Optional)
- Standard: 5’, with quick connect fitting and locking clasp
Intrinsic Safety
- Class I Division I Group D T3UL 913, CSA 22.2 No. 157, MET Labs #E112840