Images are representations only.

SS500 Moisture Analyzer

Brand: Endress+Hauser
CSA CSA
Hydrogen Compatible Hydrogen Compatible

Using patented tunable diode laser spectroscopy (TDLAS) technology, the SS500 analyzer is an economical choice for measuring H2O concentration in natural gas without coming into physical contact with the stream. The result is a sensor that does not suffer from contamination or drift due to vapor impurities such as glycol, methanol, or amines.

 

  • Natural gas quality measurements in production, storage, transportation, and distribution
  • Monitoring for natural gas pipelines, processing plants, compressor stations, gathering sites, and distribution quality
  • Suitable for use as a check-measurement device
  • Measurable ranges of up to 0-250 lb/mmscf (0-5275 ppm) H2O
Features
  • Economical real-time moisture measurements

  • Virtually maintenance-free

  • Reliable in harsh environments

  • Fast and accurate with no wet-up or dry-down delays

  • No contamination or drift due to vapor impurities such as glycol, methanol, amines, hydrogen sulfide, or mercaptans

  • NIST-traceable calibration with analog and serial outputs for remote monitoring

  • CSA certified for CSA Class 1, Division 2 or Class 1, Division 1

Using patented tunable diode laser spectroscopy (TDLAS) technology, the SS500 analyzer is an economical choice for measuring H2O concentration in natural gas without coming into physical contact with the stream. The result is a sensor that does not suffer from contamination or drift due to vapor impurities such as glycol, methanol, or amines.

 

  • Natural gas quality measurements in production, storage, transportation, and distribution
  • Monitoring for natural gas pipelines, processing plants, compressor stations, gathering sites, and distribution quality
  • Suitable for use as a check-measurement device
  • Measurable ranges of up to 0-250 lb/mmscf (0-5275 ppm) H2O
Features
  • Economical real-time moisture measurements

  • Virtually maintenance-free

  • Reliable in harsh environments

  • Fast and accurate with no wet-up or dry-down delays

  • No contamination or drift due to vapor impurities such as glycol, methanol, amines, hydrogen sulfide, or mercaptans

  • NIST-traceable calibration with analog and serial outputs for remote monitoring

  • CSA certified for CSA Class 1, Division 2 or Class 1, Division 1

Specifications

Certifications & Approvals

CSA CSA

Measuring principle

  • TDLAS

Channels

  • 1

Analyte and Measurement ranges

  • H2O (Moisture): 5 to 422 ppmv (minimum)
  • H20( Moisture): 5 to 2110 ppmv (maximum)

Measured Variables

  • Concentration
  • Dew Point
  • Cell Pressure
  • Cell Temperature

Ambient Temperature range

  • -20 to 50°C (-4 to 122°F)

Operating Pressure range

  • Inlet Pressure: 140 to 350 kPa (20 to 50 psig)
  • Sample Cell: 700 to 1400 mbara

Analyzer Wetted materials

  • 316L stainless steel
  • FKM O-Rings
  • Glass

Power supply

  • 100 to 240 VAC, 50 to 60 Hz
  • 9 to 16 VDC or 18 to 32 VDC - optional
  • 1 Amp maximum at 120 VAC
  • 1.6 Amps at 24VDC, 3.2 Amps at 12 VDC

Communication

  • Analog Output: 1 or 2 4-20mA Isolated, 1200 ohms at 24
  • VDC max load
  • Serial: RS232C
  • Protocol: Modbus Gould RTU or Daniel RTU or ASCII
  • Alarms: 2, General Fault and Concentration Alarms via
  • Modbus and Analog Output(s)
  • Housing materials
  • Electronics: 304 stainless steel (Class I Division 2)
  • Sample System Panel: anodized aluminum

Hazardous area approvals

  • CSA Class I, Division 2
  • CSA Class I, Zone 2

Degree of protection

  • Type 3R (Class I Division 2)

Configure

Configuration for Endress+Hauser products is available directly on their website. Visit the link below to configure your SS500 Moisture Analyzer and generate your unique product number.

Submit a request for information form on this product page with the unique product number in order for our team to assist you faster. If you need assistance with an Endress+Hauser configurator, please contact our team. 