Performance at 77° F / 25° C
- Accuracy: ± 0.25 % BFSL
- Stability (1 year): ± 0.25 % Full Scale, typical
- Over Range Protection: 2X Rated Pressure, Min.
- Burst Pressure: 5X or 40,000 psi (whichever is less)
- Standard Pressure Ranges: 0-2 psi, 0-20 psi, 0-100 psi, 0-500 psi, 0-1,000 psi, 0-3,000 psi, 0-5,000 psi, 0-10,000 psi
- 1/2" Male NPT connexion, 316-SS
Operating Range
- -40 to +176° F
- -40 to +80° C
Operating Temperature
- -40° to +176° F
- -40° to +80° C
Power
- Four D Cell Lithium battery pack
- Field replaceable
Battery Life
- 8+ years with an hourly report and 30 s pressure sample interval
Data Interface
- LTE CAT M1 MQTT with SparkPlug B
Data Transmission
- Report interval 1 min to 12 hours (min, max, avg, Time of Call)
- Configurable report on exception threshold
- Configurable sampling rate as fast as every 5 seconds
Cat-M1 Supported Bands
- B1, B2, B3, B4, B5, B8, B12, B13, B14, B17, B20, B25, B26, B28, B66
Antenna Type
- Internal: LTE with Internal GPS
- External: LTE (SMA Connector)
Enclosure
- Industrial polycarbonate UV Rated, IP64
Safety Rating
- Class I, Div. 2 Certified, Groups A, B, C, D. Temperature Code T5. Certified to CSA C22.2 No. 213:2017, Conforms to UL 121201:2017