Absolute and Gauge Pressure Cerabar PMP71

Brand: Endress+Hauser
CSA CSA
Hydrogen Compatible Hydrogen Compatible
Extended Extended

The Cerabar PMP71 digital pressure transmitter with metallic membrane is typically used in process applications for pressure, level, volume or mass measurement in liquids or gases. PMP71 is designed for high pressure applications up to 700 bar.

Quick Setup with freely adjustable measuring range without pressure specification.

Designed according to IEC 61508 for use in SIL2/3 safety systems and available with MID Parts Certificate suitable for custody transfer applications.

Two chamber aluminum or stainless steel (316L) housing.

  • Process connections: Threads and flange connections
  • Process temperature: -40 to +125 °C (-40 to +257 °F)
  • Measuring ranges: -1/0 up to 700 bar (-15/0 up to +10,500 psi)
  • Accuracy: ±0.05%, "Platinum" ±0.025%
  • International explosion protection certificates, overfill prevention WHG, hygienic approvals, marine approvals, SIL

Features

  • Best accuracy, reproducibility and long-term stability
  • Highest safety due to gas tight feedthrough with capabilities up to SIL2/3, certified to IEC 61508
  • Easy menu-guided commissioning via local display, 4 to 20mA with HART, PROFIBUS PA, FOUNDATION Fieldbus
  • HistoROM data management concept for fast and easy commissioning, maintenance and diagnostics
  • Overload-resistant and function-monitored from the measuring cell to the electronics
  • Available with mounted manifolds: always fit, always tested for leaks
  • Seamless and independent system integration (HART/PA/FF)

The Cerabar PMP71 digital pressure transmitter with metallic membrane is typically used in process applications for pressure, level, volume or mass measurement in liquids or gases. PMP71 is designed for high pressure applications up to 700 bar.

Quick Setup with freely adjustable measuring range without pressure specification.

Designed according to IEC 61508 for use in SIL2/3 safety systems and available with MID Parts Certificate suitable for custody transfer applications.

Two chamber aluminum or stainless steel (316L) housing.

  • Process connections: Threads and flange connections
  • Process temperature: -40 to +125 °C (-40 to +257 °F)
  • Measuring ranges: -1/0 up to 700 bar (-15/0 up to +10,500 psi)
  • Accuracy: ±0.05%, "Platinum" ±0.025%
  • International explosion protection certificates, overfill prevention WHG, hygienic approvals, marine approvals, SIL

Features

  • Best accuracy, reproducibility and long-term stability
  • Highest safety due to gas tight feedthrough with capabilities up to SIL2/3, certified to IEC 61508
  • Easy menu-guided commissioning via local display, 4 to 20mA with HART, PROFIBUS PA, FOUNDATION Fieldbus
  • HistoROM data management concept for fast and easy commissioning, maintenance and diagnostics
  • Overload-resistant and function-monitored from the measuring cell to the electronics
  • Available with mounted manifolds: always fit, always tested for leaks
  • Seamless and independent system integration (HART/PA/FF)

Specifications

Certifications & Approvals

CSA CSA

Hydrogen Compatibility %

Hydrogen Compatible up to 100% Hydrogen Compatible up to 100% Hydrogen Compatible up to 30% Hydrogen Compatible up to 30% Hydrogen Compatible up to 20% Hydrogen Compatible up to 20%

Product Family

  • Cerabar

Measuring Principle

  • Absolute and Gauge Pressure

Characteristic

  • Digital transmitter with piezoresistive sensor and welded metallic membrane
  • Modular transmitter
  • Long term stability
  • Enhanced safety via self diagnostic functionsSecondary process barrier

Supply Voltage

  • 4...20 mA HART
  • 10.5...45 VDC (Non Ex): Ex ia: 10.5...30 VDC
  • PROFIBUS PA: 9...32 VDC (Non Ex)
  • FOUNDATION Fieldbus: 9...32 VDC (Non Ex)

Reference Accuracy

  • Standard: 0.05%
  • Platinum: up to 0.025%

Long Term Stability

  • 0.05 % of URL/ year
  • 0.07 % of URL/ 5 years
  • 0.1 % of URL/ 10 years

Process Temperature

  • -40…+125 °C (-40…+257 °F)

Ambient Temperature

  • -50...+85 °C (-58...+185 °F)

Measuring Cell

  • 400 mbar...700 bar (5.8 psi...10,500 psi) relative/ absolute

Smallest Calibratable Span

  • 5 mbar (0.075 psi)

Vacuum Resistance

  • 10 mbar (0.15 psi)

Max. Turn Down

  • 100:1

Max. Overpressure Limit

  • 1,050 bar (15,750 psi)

Process Connection

  • Thread: G1/2...G2, R1/2, MNPT1/2...MNPT2, R1/2
  • Flange: DN25...DN80, ASME 1"...4", JIS 10K...20K

Material Process Membrane

  • 316L, Alloy C
  • Rhodium> Gold

Material Gasket

  • None, measuring cell welded

Fill Fluid

  • Silicone oil
  • Inert oil

Material Housing

  • Die-cast aluminum
  • AISI 316L

Communication

  • 4...20 mA HART
  • 1- 5 VDC Low Power
  • PROFIBUS PA
  • FOUNDATION Fieldbus

Certificates / Approvals

  • ATEX, FM, CSA, CSA C/US, IEC Ex, JPN Ex, INMETRO, NEPSI, EAC, UK Ex

Safety Approvals

  • SIL

Design Approvals

  • EN10204-3.1
  • NACE MR0175

Marine Approvals

  • GL/ABS

Drinking Water Approvals

  • NSF

Specialities

  • Diagnostic functions

Successor

  • PMP71B

Configure

Configuration for Endress+Hauser products is available directly on their website. Visit the link below to configure your Cerabar PMP71B - pressure transmitter and generate your unique product number.

Submit a request for information form on this product page with the unique product number in order for our team to assist you faster. If you need assistance with an Endress+Hauser configurator, please contact our team. 

Click here to access the Cerabar PMP71B - pressure transmitter configurator. 

Why Choose the Endress+Hauser Cerabar PMP71B

Value Elements
  • High-Performance Pressure Measurement for Demanding Gas Sites
    • The Cerabar PMP71B is a strong fit for Canadian natural gas applications where higher pressure capability, accuracy, and long-term signal confidence are important.
    • It supports gauge and absolute pressure measurement in gases, making it useful across transmission, compression, processing, and station control applications.
  • Built for Higher-Pressure Applications
    • Compared to the PMP51B, the PMP71B is better suited for more demanding pressure points, with available measuring ranges up to 700 bar / 10,500 psi.
    • This makes it a good choice for compressor stations, high-pressure transmission assets, process skids, and applications where pressure measurement is tied to equipment protection.
  • Smart Verification Without Process Interruption
    •  Heartbeat Technology allows device health verification while the process continues running, helping operators confirm transmitter performance without unnecessary shutdowns.
    • For Canadian gas operators managing remote or critical assets, this supports better maintenance planning and fewer avoidable site visits.

 

Comparison vs. Next Best Alternative
  • Compared to a Basic Pressure Transmitter
    • A basic transmitter may provide the pressure signal, but the PMP71B adds stronger diagnostics, verification capability, and digital communication options.
    • This helps natural gas operators move beyond simple measurement and improve confidence in pressure data used for alarms, controls, and maintenance decisions.
  • Compared to Lower-Duty Pressure Transmitters
    • The PMP71B is better suited for higher-pressure and more demanding services where accuracy, stability, and verification matter more than lowest installed cost.
    • It is a strong upgrade option when operators want a transmitter that supports modern reliability programs, not just basic pressure monitoring.

 

Where Do I Use This Product and Why?
  • Compressor Stations
    • Use it on suction, discharge, interstage, seal gas, utility gas, and auxiliary pressure points where dependable pressure data supports alarms, shutdown logic, and equipment protection.
  • Transmission and High-Pressure Gas Assets
    • Use it on high-pressure pipeline monitoring points, pressure control systems, block valve sites, and station piping where accurate pressure visibility is critical.
  • Metering and Process Skids
    • Use it where pressure input is required for gas measurement, flow computer integration, process control, and remote monitoring.
    • •It is especially useful where Canadian operators need a reliable pressure transmitter for critical or hard-to-access natural gas infrastructure.