Images are representations only.

Proline Promass F 500 Coriolis flowmeter

Brand: Endress+Hauser
CSA CSA Measurement Canada Measurement Canada
Hydrogen Compatible Hydrogen Compatible

Promass F has a long-standing reputation as a highly accurate sensor. Immune to fluctuating and harsh environments it is suited for the broadest range of applications. With its innovative remote transmitter Promass F 500 maximizes installation flexibility and operational safety in demanding environments. Heartbeat Technology enables measurement reliability and extension of recalibration cycles.

 
  • Measuring principle operates independently of physical fluid properties such as viscosity or density

  • Highest measurement performance for liquids and gases under varying, demanding process conditions


Device properties

  • Mass flow: measurement error ±0.05 % (PremiumCal)

  • Medium temperature: -196 to 350 °C (-320 to 662 °F)

  • Nominal diameter: DN 8 to 250 (³⁄₈ to 10")

  • Remote version with up to 4 I/Os

  • Backlit display with touch control and WLAN access

  • Standard cable between sensor and transmitter

Features
  • Highest process safety – immune to fluctuating and harsh environments

  • Fewer process measuring points – multivariable measurement (flow, density, temperature)

  • Space-saving installation – no in-/outlet run needs

  • Full access to process and diagnostic information – numerous, freely combinable I/Os and Ethernet

  • Reduced complexity and variety – freely configurable I/O functionality

  • Integrated verification – Heartbeat Technology

Promass F has a long-standing reputation as a highly accurate sensor. Immune to fluctuating and harsh environments it is suited for the broadest range of applications. With its innovative remote transmitter Promass F 500 maximizes installation flexibility and operational safety in demanding environments. Heartbeat Technology enables measurement reliability and extension of recalibration cycles.

 
  • Measuring principle operates independently of physical fluid properties such as viscosity or density

  • Highest measurement performance for liquids and gases under varying, demanding process conditions


Device properties

  • Mass flow: measurement error ±0.05 % (PremiumCal)

  • Medium temperature: -196 to 350 °C (-320 to 662 °F)

  • Nominal diameter: DN 8 to 250 (³⁄₈ to 10")

  • Remote version with up to 4 I/Os

  • Backlit display with touch control and WLAN access

  • Standard cable between sensor and transmitter

Features
  • Highest process safety – immune to fluctuating and harsh environments

  • Fewer process measuring points – multivariable measurement (flow, density, temperature)

  • Space-saving installation – no in-/outlet run needs

  • Full access to process and diagnostic information – numerous, freely combinable I/Os and Ethernet

  • Reduced complexity and variety – freely configurable I/O functionality

  • Integrated verification – Heartbeat Technology

Specifications

Certifications & Approvals

CSA CSA Measurement Canada Measurement Canada

Hydrogen Compatibility %

Hydrogen Compatible up to 100% Hydrogen Compatible up to 100% Hydrogen Compatible up to 30% Hydrogen Compatible up to 30% Hydrogen Compatible up to 20% Hydrogen Compatible up to 20%

Sensor features

  • Highest process safety – immune to fluctuating and harsh environments.
  • Fewer process measuring points – multivariable measurement (flow, density, temperature).
  • Space‐saving installation – no in-/outlet run needs.
  • Mass flow: measurement error ±0.05 % (PremiumCal).
  • Medium temperature: –196 to 350 °C (–320 to 662 °F).
  • Nominal diameter: DN 8 to 250 (³⁄₈ to 10").

Transmitter features

  • Full access to process and diagnostic information – numerous, freely combinable I/Os and fieldbuses.
  • Reduced complexity and variety – freely configurable I/O functionality.
  • Integrated verification – Heartbeat Technology.
  • Remote version with up to 4 I/Os.
  • Backlit display with touch control and WLAN access.
  • Standard cable between sensor and transmitter.

Nominal diameter range

  • DN 8 to 250 (⅜ to 10")

Wetted materials

  • Connection: 1.4404 (316/316L); Alloy C22, 2.4602 (UNS N06022); 1.4301 (F304)
  • Measuring tube: 1.4539 (904L); 1.4404 (316/316L); Alloy C22, 2.4602 (UNS N06022)

Measured variables

  • Mass flow, density, temperature, volume flow, corrected volume flow, reference density, concentration

Max. measurement error

  • Mass flow (liquid): ±0.10 % (standard), 0.05 % (option)
  • Volume flow (liquid): ±0.10 %
  • Mass flow (gas): ±0.25 %
  • Density (liquid): ±0.0005 g/cm³

Measuring range

  • 0 to 2 200 000 kg/h (0 to 80 840 lb/min)

Max. process pressure

  • PN 100, Class 600, 63K

Medium temperature range

  • Standard: –50 to +150 °C (–58…+302 °F)
  • Option: –50 to +240 °C (–58…+464 °F)
  • High temperatur option: –50 to +350 °C (–58…+662 °F)
  • Option: –196 to +150 °C (–320 to +302 °F)

Ambient temperature range

  • Standard: –40 to +60 °C (–40 to +140 °F)
  • Option: –60 to +60 °C (–76 to +140 °F)

Sensor housing material

  • Standard: 1.4301 (304), corrosion resistant
  • Option: 1.4404 (316L)
  • Sensor connection housing (standard): AlSi10Mg, coated
  • Sensor connection housing (option): 1.4301 (304); 1.4404 (316L); 1.4409 (CF3M) similar to 316L

Transmitter housing material

  • AlSi10Mg, coated; 1.4409 (CF3M) similar to 316L; Polycarbonat

Degree of protection

  • Sensor remote version (standard): IP66/67, type 4X enclosure
  • Sensor remote version (option): IP69.
  • Transmitter remote version: IP66/67, Type 4X enclosure

Display/Operation

  • 4-line backlit display with touch control (operation from outside)
  • Configuration via local display and operating tools possible

Outputs

  • 4 outputs: 4-20 mA HART (active/passive) 4-20 mA WirelessHART 4-20 mA (active/passive)
  • Pulse/frequency/switch output (active/passive)
  • Double pulse output (active/passive)
  • Relay output

Inputs

  • Status input 4-20 mA input

Digital communication

  • HART
  • PROFIBUS DP
  • PROFIBUS PA
  • FOUNDATION Fieldbus
  • Modbus RS485
  • PROFINET
  • PROFINET over Ethernet-APL
  • Ethernet/IP
  • OPC-UA

Power supply

  • DC 24 V
  • AC 100 to 230 V
  • AC 100 to 230 V / DC 24 V (non-hazardous area)

Hazardous area approvals

  • ATEX
  • IECEx
  • cCSAus
  • NEPSI
  • INMETRO
  • EAC
  • KC

Product safety

  • CE
  • C-tick
  • EAC marking

Functional safety

  • Functional safety according to IEC 61508, applicable in safety-relevant applications in accordance with IEC 61511

Metrological approvals and certificates

  • Calibration performed on accredited calibration facilities (acc. to ISO/IEC 17025) Heartbeat Technology complies with the requirements for measurement traceability according to ISO 9001:2015 – Section 7.1.5.2 a (TÜV SÜD attestation) MI-005 (Liquids other than water, Hydrocarbons, LPG, cryogenic liquids) NTEP (Liquids other than water, LPG, cryogenic liquids) MC (Liquids other than water, gases, cryogenic liquids) MI-002, PTB

Pressure approvals and certificates

  • PED, CRN, AD 2000

Marine approvals and certificates

  • certificates LR approval, DNV approval, ABS approval, BV approval, CCS approval

Material certificates

  • 3.1 material NACE MR0175/MR0103, PMI; welding test acc. to EN ISO, ASME, NORSOK

Hygienic approvals and certificates

  • 3-A, EHEDG, cGMP