Dival 160 AP Pressure Regulator

Brand: Pietro Fiorentini S.p.A.
When requesting information, please download the Fillable PDF to provide details about your regulator use case. Instructions for completing the form are found in the footer of the document. Once completed, please upload the document with the Request for Information.

Dival 160 AP by Pietro Fiorentini is a direct-operated gas pressure regulator controlled by a diaphragm and contrasting regulated spring action.
Classified as Fail Open according to the European Standard EN 334, it can be used with previously cleaned gaseous fluids. It is particularly suitable for high-pressure transmission systems and for medium pressure natural gas distribution networks.

Dival 160 AP is Hydrogen Ready for NG-H2 blending. Single-stage pressure-reducing Valves Type DIVAL 160AP.
For industrial and chemical engineering applications. Suitable for natural gas and all non-corrosive gaseous media.

Features
  • Accuracy class AC: up to 5 (depending on working conditions)
  • Nominal sizes DN: 1″
  • Lock-up pressure class SG: up to 10 (depending on working conditions)
  • Design pressure: 85 bar
  • Design temperature: from -20 °C to +60 °C
  • Connections: class 300 and 600 RF or RTJ according to ASME B16.5
  • Range of downstream pressure Wd: from 0.85 to 4.5 bar
  • Inlet pressure range bpu: from 1.4 to 85 bar
show more

Dival 160 AP by Pietro Fiorentini is a direct-operated gas pressure regulator controlled by a diaphragm and contrasting regulated spring action.
Classified as Fail Open according to the European Standard EN 334, it can be used with previously cleaned gaseous fluids. It is particularly suitable for high-pressure transmission systems and for medium pressure natural gas distribution networks.

Dival 160 AP is Hydrogen Ready for NG-H2 blending. Single-stage pressure-reducing Valves Type DIVAL 160AP.
For industrial and chemical engineering applications. Suitable for natural gas and all non-corrosive gaseous media.

Features
  • Accuracy class AC: up to 5 (depending on working conditions)
  • Nominal sizes DN: 1″
  • Lock-up pressure class SG: up to 10 (depending on working conditions)
  • Design pressure: 85 bar
  • Design temperature: from -20 °C to +60 °C
  • Connections: class 300 and 600 RF or RTJ according to ASME B16.5
  • Range of downstream pressure Wd: from 0.85 to 4.5 bar
  • Inlet pressure range bpu: from 1.4 to 85 bar

Specifications

Accuracy Class

  • Up to 5

Available Size DN

  • 1”

Closing Pressure Class SG

  • Up to 10

Design Pressure

  • 85 bar

Design Temperature

  • -10° to 60° C

Flanging

  • Class 300-600 RF Accordnig to ANSI B16.5

Outlet Pressure Range of Wd

  • 0.85 to 4.5

Range of Inlet Pressure Bpu

  • 1.4 to 85 bar