Images are representations only.

Reval 182 Gas Pressure Regulator

Brand: Pietro Fiorentini S.p.A.
When requesting information, please download the Fillable PDF to provide details about your regulator use case. Instructions for completing the form are found in the footer of the document. Once completed, please upload the document with the Request for Information.
Reval 182 is one of the pilot-operated gas pressure regulators by Pietro Fiorentini.

This device is suitable for use with previously filtered non-corrosive gases, and it is mainly used for medium and low pressure natural gas distribution networks.

According to the European Standard EN 334, it is classified as Fail Close.

Reval 182 is Hydrogen Ready for NG-H2 blending.
Features
  • Accuracy class: up to 2.5
  • Available size DN: 1″, 2″, 2″ 1/2, 3″, 4″, 6″, 8″, 10″
  • Closing pressure class SG: up to 5
  • Design pressure: up to 25 bar
  • Design temperature: from -20° to 60° C (higher or lower temperatures on demand)
  • Flanging: class 150 RF or RTJ according to ASME B16.5, and PN 16, 25 and 40 according to ISO 7005
  • Minimum working differential pressure: 100 mbar
  • Outlet pressure range of Wd: from 6 to 12,000 mbar
  • Range of inlet pressure bpu: from 0.2 to 25 bar
show more
Reval 182 is one of the pilot-operated gas pressure regulators by Pietro Fiorentini.

This device is suitable for use with previously filtered non-corrosive gases, and it is mainly used for medium and low pressure natural gas distribution networks.

According to the European Standard EN 334, it is classified as Fail Close.

Reval 182 is Hydrogen Ready for NG-H2 blending.
Features
  • Accuracy class: up to 2.5
  • Available size DN: 1″, 2″, 2″ 1/2, 3″, 4″, 6″, 8″, 10″
  • Closing pressure class SG: up to 5
  • Design pressure: up to 25 bar
  • Design temperature: from -20° to 60° C (higher or lower temperatures on demand)
  • Flanging: class 150 RF or RTJ according to ASME B16.5, and PN 16, 25 and 40 according to ISO 7005
  • Minimum working differential pressure: 100 mbar
  • Outlet pressure range of Wd: from 6 to 12,000 mbar
  • Range of inlet pressure bpu: from 0.2 to 25 bar

Specifications

Accuracy Class

  • Up to 2.5

Available Size DN

  • 10”
  • 6”
  • 4”
  • 3”
  • 2-1/2”
  • 2”
  • 1”
  • 8”

Closing Pressure Class SG

  • Up to 5

Design Pressure

  • Up to 25 bar

Design Temperature

  • -20° to 60° C

Flanging

  • ANSI 150 RF o RTJ According to ANSI B16.5 and PN 16/25/40 According to ISO 7005

Maximum Working Differential Pressure

  • 25 bar

Minimum Working Differential Pressure

  • 100 mbar

Outlet Pressure Range of Wd

  • 6 to 12,000 mbar

Range of Inlet Pressure Bpu

  • 0.2 to 25 bar